Data centres & high capacity
Backups running late? Start with volume and route.
Connecting data centres means sizing traffic and deciding who operates transmission. Compare Ethernet, Wave, Spectrum and Dark Fibre against your transfer window, equipment and need for control.
Let’s talk
Colt capabilities to consider
Connection inside the data centre
The service may be delivered in an interconnection room (MMR, Meet-Me Room) or a shared equipment area (CEA, Common Equipment Area). Internal cabling (a cross-connect) connects this point to the customer’s equipment cabinet (rack).
External networkData centre
Interconnection pointHandover point
Customer equipment cabinetOptional private enclosure (cage)
The handover point, internal connection and responsibilities must be validated. A Colt-connected data centre is not necessarily operated by Colt.
When it matters
More capacity helps when the connection is the bottleneck.
- Backups miss their window
- Compare volume, available time and storage performance before upgrading the circuit.
- More traffic between centres
- Measure peaks and growth to decide whether to retain Ethernet or consider optical transport.
- More optical control
- Identify available equipment and expertise before taking responsibility for transponders or all transmission.
- Equipment at another centre
- Specify space, power and interconnections to compare a rack with a private enclosure.
Criteria for your project
- Who operates transmission?
- Wave, Spectrum and Dark Fibre divide responsibilities differently; compare them with your equipment and operating capability.
- Do routes share a risk?
- Review paths, building entries and common points: two circuits can fail for the same physical reason.
- What should happen on failure?
- Define priority traffic and tolerable recovery time to choose protection and test the alternative path.
- Can you use the capacity?
- Check volume and transfer window against interfaces, equipment and storage; circuit speed alone does not explain performance.
- Where is service delivered?
- Identify the interconnection room, internal connection and rack; assign who orders and operates each segment.
Who takes responsibility?

Demarcation, equipment and maintenance are specified in the offer; this is not a better-to-worse ranking.
Questions worth asking
Is Dark Fibre always better?
No. Dark Fibre supplies unlit fibre and requires you to operate transmission; Wave provides a managed optical service. Spectrum is another option if you retain your own transponders. Bring routes, capacity and equipment details to compare responsibilities and compatibility.
What does a Colt-connected data centre mean?
Colt connectivity does not mean Colt operates the centre. Agree the handover, internal cabling, space and power with the party responsible for each segment.
The service may be delivered in an interconnection room (MMR, Meet-Me Room) or a shared equipment area (CEA, Common Equipment Area). Internal cabling (a cross-connect) connects this point to the customer’s equipment cabinet (rack).
External networkData centre
Interconnection pointHandover point
Customer equipment cabinetOptional private enclosure (cage)
An isolated product is rarely the complete answer.
Replication between centres
Illustrative case: a nightly backup exceeds its window. Compare Ethernet or Wave against volume and interfaces, with internal connections at both ends. Measure storage too, and test recovery over the planned alternative route.
Controlled optical scale
Illustrative case: you own transponders and need to grow. Spectrum lets you consider Colt’s line system; Dark Fibre means taking responsibility for transmission. Compare compatibility, maintenance and routes with managed Wave before deciding.
Explore Colt’s sources
- Dark Fibre · operating the fibreOpens in a new tab
- Wave · optical transportOpens in a new tab
- Spectrum · transponders and line systemOpens in a new tab
- Ethernet · connecting data centresOpens in a new tab
- Rack · space and connectionsOpens in a new tab
- Cage · private enclosureOpens in a new tab
Availability, coverage, capabilities, SLAs and timelines are subject to technical validation and contract. No diagram is a service guarantee.
What challenge would you like to solve?
Tell us what is happening and what needs to change. You do not need to know the catalogue.
What happens next?
- Understand the context
What’s changing, where your teams work and what cannot fail. Still defining the brief? We can help structure it.
- Design the options
Bring needs, Colt capabilities and technical criteria together. Compare alternatives and explain dependencies and limits.
- Validate before committing
Coverage, feasibility, responsibilities and terms. A commercial proposal is developed with the relevant specialists.
ColtPlatinum guides the project and coordinates commercial discussions and follow-up. Colt validates feasibility, enters into the service contract, and provisions, installs and delivers the services.
Availability, coverage, capabilities, SLAs and timelines are subject to technical validation and contract. No diagram is a service guarantee.